{"product_id":"cavo-solare-fotovoltaico-4mm-nero-serie-auris-h1z2z2-k","title":"Cavo Solare Fotovoltaico 4mm² Nero Serie Auris H1Z2Z2-K","description":"\u003cp\u003e📐 \u003cstrong\u003eH1Z2Z2-K · 1×4 mm² · Nero\u003c\/strong\u003e · 1,5 kV DC · Rame stagnato · Guaina XLPO ø5,6 mm · -40\/+90 °C · Matassa \u003cstrong\u003e100 m\u003c\/strong\u003e · CEI EN 50618\u003cbr\u003e🔧 \u003cstrong\u003eDifficoltà:\u003c\/strong\u003e 3\/5 (impianto in continua) · 🎯 \u003cstrong\u003eIdeale per:\u003c\/strong\u003e stringhe fotovoltaiche residenziali e commerciali, collegamento pannelli-inverter\u003c\/p\u003e\u003ch2\u003eCavo solare fotovoltaico 4mm² nero H1Z2Z2-K serie Auris, matassa da 100 m\u003c\/h2\u003e\u003cp\u003eCavo unipolare \u003cstrong\u003eH1Z2Z2-K\u003c\/strong\u003e, lo standard specifico per il fotovoltaico: non è un cavo elettrico generico adattato, ma un conduttore progettato per i \u003cstrong\u003e1500 V in corrente continua\u003c\/strong\u003e e per restare esposto al sole per l'intera vita dell'impianto. Conduttore in \u003cstrong\u003erame stagnato\u003c\/strong\u003e a 56 fili, guaina in \u003cstrong\u003eXLPO reticolato\u003c\/strong\u003e resistente a raggi UV, ozono e agenti atmosferici, doppio isolamento in \u003cstrong\u003eclasse II\u003c\/strong\u003e. Il colore \u003cstrong\u003enero\u003c\/strong\u003e identifica per convenzione il \u003cstrong\u003epolo negativo\u003c\/strong\u003e della stringa. Fornito in matassa da \u003cstrong\u003e100 metri\u003c\/strong\u003e, certificato \u003cstrong\u003eCEI EN 50618\u003c\/strong\u003e.\u003c\/p\u003e\u003ch3\u003eVantaggi tecnici\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e☀️ \u003cstrong\u003eGuaina XLPO reticolata:\u003c\/strong\u003e resiste a UV, ozono e sbalzi termici per decenni, dove un cavo comune in PVC si crepa in poche stagioni\u003c\/li\u003e\n\u003cli\u003e🔋 \u003cstrong\u003e1,5 kV in corrente continua:\u003c\/strong\u003e tensione di esercizio dimensionata per le stringhe moderne, con tensione di prova a 15 kV DC\u003c\/li\u003e\n\u003cli\u003e🧲 \u003cstrong\u003eRame stagnato:\u003c\/strong\u003e lo strato di stagno protegge il conduttore da corrosione e ossidazione, critico su impianti che restano in opera vent'anni e più\u003c\/li\u003e\n\u003cli\u003e🌡️ \u003cstrong\u003eDa -40 a +90 °C\u003c\/strong\u003e in esercizio, fino a \u003cstrong\u003e200 °C per 5 secondi\u003c\/strong\u003e in cortocircuito\u003c\/li\u003e\n\u003cli\u003e🛡️ \u003cstrong\u003eClasse di isolamento II:\u003c\/strong\u003e doppio isolamento, requisito per il lato corrente continua\u003c\/li\u003e\n\u003cli\u003e🔥 \u003cstrong\u003eEuroclasse Eca\u003c\/strong\u003e secondo il regolamento CPR\u003c\/li\u003e\n\u003cli\u003e📏 \u003cstrong\u003eRaggio di curvatura 28 mm:\u003c\/strong\u003e maneggevole anche dietro i moduli e dentro le canaline\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eScheda tecnica\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSigla\u003c\/td\u003e\n\u003ctd\u003eH1Z2Z2-K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormazione cavo\u003c\/td\u003e\n\u003ctd\u003e1 × 4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormazione conduttori\u003c\/td\u003e\n\u003ctd\u003e56 × 0,3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMateriale conduttori\u003c\/td\u003e\n\u003ctd\u003eRame stagnato\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuaina \/ diametro esterno\u003c\/td\u003e\n\u003ctd\u003eXLPO · ø 5,6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColore\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNero\u003c\/strong\u003e — polo negativo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensione di esercizio\u003c\/td\u003e\n\u003ctd\u003e1,0 kV AC · \u003cstrong\u003e1,5 kV DC\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensione di prova\u003c\/td\u003e\n\u003ctd\u003e6,5 kV AC o 15 kV DC per 5 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistenza conduttori\u003c\/td\u003e\n\u003ctd\u003e5,09 Ω\/km a 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistenza isolamento\u003c\/td\u003e\n\u003ctd\u003e580 Ω\/km a 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura di esercizio\u003c\/td\u003e\n\u003ctd\u003e-40 \/ +90 °C · 200 °C per 5 s in cortocircuito\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClasse di isolamento\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRaggio minimo di curvatura\u003c\/td\u003e\n\u003ctd\u003e28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrazione di posa\u003c\/td\u003e\n\u003ctd\u003e1,5 kg\/mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicazione\u003c\/td\u003e\n\u003ctd\u003ePosa fissa, interrata o in esterno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClasse CPR\u003c\/td\u003e\n\u003ctd\u003eEca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificazioni\u003c\/td\u003e\n\u003ctd\u003eCEI EN 50618 · RoHS · REACH · EN 50575:2014+A1:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLunghezza \/ confezione\u003c\/td\u003e\n\u003ctd\u003e100 m in scatola\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClasse ETIM\u003c\/td\u003e\n\u003ctd\u003eEC002928\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarca\u003c\/td\u003e\n\u003ctd\u003eAlphaSolar — serie Auris\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eWTRFV4-N1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e8017443687097\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eCome scegliere: sezione e colore\u003c\/h3\u003e\u003cp\u003eLa \u003cstrong\u003esezione\u003c\/strong\u003e dipende dalla corrente della stringa e dalla distanza; il \u003cstrong\u003ecolore\u003c\/strong\u003e dalla polarità.\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCavo\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSezione\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePolarità\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eQuando sceglierlo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuesto\u003c\/td\u003e\n\u003ctd\u003e4 mm²\u003c\/td\u003e\n\u003ctd\u003eNero — negativo\u003c\/td\u003e\n\u003ctd\u003eStringhe standard, distanze contenute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/cavo-solare-fotovoltaico-4mm-rosso-serie-auris-h1z2z2-k\"\u003e4 mm² rosso\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 mm²\u003c\/td\u003e\n\u003ctd\u003eRosso — positivo\u003c\/td\u003e\n\u003ctd\u003eIl corrispondente positivo della stessa stringa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/cavo-fotovoltaico-6mmq-1500kv-per-fotovoltaico-nero\"\u003e6 mm² nero\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 mm²\u003c\/td\u003e\n\u003ctd\u003eNero — negativo\u003c\/td\u003e\n\u003ctd\u003eCorrenti elevate o tratte lunghe, per contenere la caduta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/cavo-solare-6mmq-1500kv-per-fotovoltaico-rosso-100mt\"\u003e6 mm² rosso\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 mm²\u003c\/td\u003e\n\u003ctd\u003eRosso — positivo\u003c\/td\u003e\n\u003ctd\u003eIl corrispondente positivo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eIl Consiglio dell'Esperto\u003c\/h3\u003e\u003cdiv style=\"background-color: #f8fafc; border-left: 5px solid #1e3a8a; padding: 20px; border-radius: 4px; display: flex; flex-wrap: wrap; align-items: flex-start; gap: 20px;\"\u003e\n\u003cdiv style=\"flex: 1 1 280px; min-width: 0;\"\u003e\n\u003cp style=\"margin-top: 0; color: #1e3a8a; font-weight: bold; font-size: 1.05em;\"\u003e🔍 Il Consiglio dell'Esperto:\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0; line-height: 1.6;\"\u003ePrima cosa, quella che non ammette eccezioni: sul lato corrente continua di un impianto fotovoltaico \u003cstrong\u003esi usa solo cavo H1Z2Z2-K\u003c\/strong\u003e. Un FROR, un H07V-K o un cavo \"da esterno\" generico non vanno bene, e non per pignoleria normativa: sono pensati per la corrente alternata a 230-400 V, mentre qui si lavora a \u003cstrong\u003e1500 V in continua\u003c\/strong\u003e, dove un arco elettrico non si estingue da solo come nell'alternata. Aggiungi che la guaina in PVC sotto il sole si irrigidisce e si crepa nel giro di poche stagioni, e capisci perché la XLPO reticolata costa di più. Sul \u003cstrong\u003ecolore\u003c\/strong\u003e: la convenzione vuole \u003cstrong\u003erosso il positivo e nero il negativo\u003c\/strong\u003e, e va rispettata anche se elettricamente i due cavi sono identici — chi verrà dopo di te a fare manutenzione si fiderà di quel colore. Compra sempre le due matasse in coppia. Ultima nota sulla \u003cstrong\u003esezione\u003c\/strong\u003e: i 4 mm² coprono la gran parte delle stringhe residenziali, ma se la distanza tra campo e inverter è importante, fai il conto della \u003cstrong\u003ecaduta di tensione\u003c\/strong\u003e e valuta i 6 mm². In continua ogni volt perso per strada è resa che non arriva all'inverter, per vent'anni.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0260\/6222\/5485\/files\/Chi_siamo_oniroview.jpg?v=1751647335\" style=\"width: 100px; height: 100px; object-fit: cover; border-radius: 50%; border: 2px solid #1e3a8a; flex-shrink: 0;\" alt=\"Esperto Oniroview\"\u003e\n\u003c\/div\u003e\u003ch3\u003eContenuto della confezione\u003c\/h3\u003e\u003cp\u003e📦 1× Matassa da 100 m di cavo solare H1Z2Z2-K 1×4 mm² nero, in scatola.\u003c\/p\u003e\u003ch3\u003eGaranzia \u0026amp; Sicurezza\u003c\/h3\u003e\u003cp\u003e✅ Garanzia 2 anni D.Lgs. 170\/2021 · 📜 CEI EN 50618, RoHS, REACH, Euroclasse Eca · ⚠️ Impianto in corrente continua ad alta tensione: la posa e le connessioni vanno eseguite da personale qualificato, con moduli oscurati o sezionati · 📦 Spedizione da Catania entro 24h lavorative.\u003c\/p\u003e","brand":"Alpha Elettronica","offers":[{"title":"Default Title","offer_id":51076781211987,"sku":"WTRFV4-N1","price":145.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0260\/6222\/5485\/files\/CavoSolareFotovoltaico6mm_NeroSerieAurisH1Z2Z2-K.jpg?v=1748360155","url":"https:\/\/zanqivorel.online\/products\/cavo-solare-fotovoltaico-4mm-nero-serie-auris-h1z2z2-k","provider":"Oniroview","version":"1.0","type":"link"}