{"product_id":"sensore-movimento-pir-12-24v-contatto-pulito-per-controller-effetto-running","title":"Infrared Sensor Clean Contact PIR 12-24V IP65 for Running Effect Controller","description":"\u003cp\u003e\u003cstrong\u003ePower supply:\u003c\/strong\u003e 12-24V AC\/DC | \u003cstrong\u003eOutput:\u003c\/strong\u003e Dry Contact (1 NO) | \u003cstrong\u003eProtection:\u003c\/strong\u003e IP65\u003cbr\u003e 🔧 \u003cstrong\u003eDifficulty:\u003c\/strong\u003e 3\/5 | 🎯 \u003cstrong\u003eIdeal for:\u003c\/strong\u003e Electricians, Home Automation Installers, LED Integrators.\u003c\/p\u003e\n\n\u003ch2\u003e Motion Detector for Automation and \"Running Light\" Scenarios\u003c\/h2\u003e\n\n\u003cp\u003e Most commercial sensors output voltage (230V) when activated, risking burning the logic inputs of modern LED controllers. This \u003cstrong\u003eJolight\u003c\/strong\u003e sensor solves the problem at its root: it offers a \u003cstrong\u003edry contact\u003c\/strong\u003e output, galvanically separated from the power supply.\u003c\/p\u003e\n\n\u003cp\u003e It is the specific technical solution for driving control units such as the \u003cstrong\u003eALC244 (Running Effect)\u003c\/strong\u003e or home automation systems that require a simple circuit closing input (NO), guaranteeing total versatility thanks to the extended 12-24V AC\/DC power supply.\u003c\/p\u003e\n\n\u003ch3\u003e Technical Analysis and Benefits for the Installer\u003c\/h3\u003e\n\n\u003cul\u003e\n\n \u003cli\u003e🔧 \u003cstrong\u003eDry Contact Logic:\u003c\/strong\u003e Unlike traditional PIRs, the internal relay (max 5A) works as a pure switch. This allows it to be interfaced directly with the P1\/P2 inputs of sequential controllers without the need for additional relays.\u003c\/li\u003e\n\n\u003cli\u003e 💧 \u003cstrong\u003eReal IP65 Outdoor:\u003c\/strong\u003e The sealed housing allows for installation in humid environments, outdoor entrances, or gardens. Ideal for creating welcoming lighting effects (e.g., walkways) that extend from the outside in.\u003c\/li\u003e\n\n\u003cli\u003e ⚙️ \u003cstrong\u003ePrecise Calibration:\u003c\/strong\u003e The trimmers allow you to exclude daytime activation (Lux 3-2000) and manage the switch-off delay (10s - 8min), avoiding the lights from flickering when switching on quickly.\u003c\/li\u003e\n\n \u003cli\u003e🔄 \u003cstrong\u003ePower Supply Flexibility:\u003c\/strong\u003e Accepts both DC and AC power in the 12-24V range. This simplifies wiring in systems where an LED strip power supply is already present, eliminating the need for dedicated transformers just for the sensor. \u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/287JmYXOLhY?si=Zga4diM5KpIzJzg1\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\n\u003ch3\u003e Technical Data Sheet \u003c\/h3\u003e\n\n\u003ctable width=\"100%\" border=\"1\" cellpadding=\"5\" cellspacing=\"0\" style=\"border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cstrong\u003eBrand\u003c\/strong\u003e\n\u003c\/td\u003e\n\n\u003ctd\u003e Jolight\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\n\u003c\/td\u003e\n\n\u003ctd\u003e 12-24V AC\/DC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cstrong\u003eStandby Consumption\u003c\/strong\u003e\n\u003c\/td\u003e\n\n\u003ctd\u003e 0.5 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cstrong\u003eExit Type\u003c\/strong\u003e\n\u003c\/td\u003e\n\n\u003ctd\u003e Clean Contact (1 NO - Normally Open)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cstrong\u003eMax Relay Load\u003c\/strong\u003e\n\u003c\/td\u003e\n\n\u003ctd\u003e 5A (Supports up to 230V on the contact)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cstrong\u003eDetection Range\u003c\/strong\u003e\n\u003c\/td\u003e\n\n\u003ctd\u003e 360° on Ø 6 meters (at h 2.5m)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cstrong\u003eIP Rating\u003c\/strong\u003e\n\u003c\/td\u003e\n\n\u003ctd\u003e IP65 (Indoor\/Outdoor)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cstrong\u003eTime Adjustment\u003c\/strong\u003e\n\u003c\/td\u003e\n\n\u003ctd\u003e 10 seconds - 8 minutes\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cstrong\u003eLight Regulation\u003c\/strong\u003e\n\u003c\/td\u003e\n\n\u003ctd\u003e 3 - 2000 Lux\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cstrong\u003eDimensions\u003c\/strong\u003e\n\u003c\/td\u003e\n\n\u003ctd\u003e 55.4 x 36.8 x 23.5 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e \u003cstrong\u003eOperating Temp.\u003c\/strong\u003e\n\u003c\/td\u003e\n\n\u003ctd\u003e -10°C \/ +40°C \u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #d32f2f; padding: 20px; border-radius: 4px; display: flex; align-items: start; gap: 20px;\"\u003e\n\n\u003cdiv style=\"flex: 1;\"\u003e\n\n\u003cp style=\"margin-top: 0; color: #d32f2f; font-weight: bold;\"\u003e 💡 Expert Advice:\u003c\/p\u003e\n\n \u003cp style=\"margin-bottom: 0;\"\u003eTo achieve perfect automation with the \u003cstrong\u003eALC244\u003c\/strong\u003e controller, use these sensors as flow triggers. Connect the input sensor to \u003cstrong\u003eP1\u003c\/strong\u003e : upon detection, the strip will turn on with a progressive \"Running\" effect and remain steady for the set time. Connect the output sensor to \u003cstrong\u003eP2\u003c\/strong\u003e : when you pass by, it will send the command for the \u003cstrong\u003ereverse switch-off\u003c\/strong\u003e (return). Place them strategically to precisely synchronize the light with your passage. \u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0260\/6222\/5485\/files\/Chi_siamo_oniroview.jpg?v=1751647335\" style=\"width: 100px; height: 100px; object-fit: cover; border-radius: 50%; border: 2px solid #d32f2f;\" alt=\"Oniroview Expert\"\u003e\n\n\u003c\/div\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003ch3\u003e Complete your Project\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e 🔗 \u003cstrong\u003eSequential LED Controller (ALC244):\u003c\/strong\u003e Required to create the running light effect.\u003c\/li\u003e\n\n\u003cli\u003e 🔗 \u003cstrong\u003e24V Power Supply:\u003c\/strong\u003e To power both sensors and LED strips stably.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cdiv\u003e\n\n\u003ch3\u003e Quick FAQs\u003c\/h3\u003e\n\n\u003cdiv\u003e\n\n\u003ch4 style=\"font-size: 1em; margin-bottom: 5px;\" itemprop=\"name\"\u003e Can I use this sensor to turn on a 220V light bulb?\u003c\/h4\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n \u003cp\u003eYes. Although the sensor requires a 12-24V power supply (due to its internal electronics), the output contact (relay) is \"dry\" and supports loads up to 230V 5A. You can therefore use it to interrupt the phase of a traditional lamp. \u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\n\u003ch4 style=\"font-size: 1em; margin-bottom: 5px;\" itemprop=\"name\"\u003e How do you connect two sensors for the running effect?\u003c\/h4\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003cp\u003e To achieve the bidirectional effect with the ALC244 controller, connect the output (NO\/COM) of the first sensor to input P1 (Start) and the output of the second sensor to input P2 (Stop\/Reverse). This allows the system to recognize the direction of travel.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch3\u003e Package Contents\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e 📦 1x Jolight PIR Sensor 12-24V IP65\u003c\/li\u003e\n\n\u003cli\u003e 📦 Screws and plugs for ceiling\/wall fixing\u003c\/li\u003e\n\n\u003cli\u003e 📦 Instruction manual and diagrams\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e Warranty \u0026amp; Security\u003c\/h3\u003e\n\n\u003cp\u003e This device complies with \u003cstrong\u003eCE\u003c\/strong\u003e and \u003cstrong\u003eRoHS\u003c\/strong\u003e regulations. Its Class II construction and \u003cstrong\u003eIP65\u003c\/strong\u003e rating ensure complete safety even in outdoor environments or bathrooms.\u003cbr\u003e ✅ \u003cstrong\u003e2-Year Italian Warranty.\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp\u003eFast shipping in 24\/48 hours and direct technical support from the Oniroview team in Catania for custom configurations.\u003c\/p\u003e","brand":"Jolight","offers":[{"title":"Default Title","offer_id":48977733517651,"sku":"23-123C","price":16.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0260\/6222\/5485\/files\/SensoreMovimentoPIR12-24VContattoPulitoperControllerEffettoRunning.jpg?v=1719918383","url":"https:\/\/zanqivorel.online\/en\/products\/sensore-movimento-pir-12-24v-contatto-pulito-per-controller-effetto-running","provider":"Oniroview","version":"1.0","type":"link"}