{"product_id":"gruppo-di-continuita-6kw-online-tower-6000va","title":"6KW Online Tower 6000VA UPS ","description":"\u003cdiv class=\"product-description-container\"\u003e\n\n\u003cdiv style=\"background-color: #f4f4f4; padding: 15px; border-radius: 4px; margin-bottom: 20px; font-size: 0.9em;\"\u003e\n\n\u003cp style=\"margin: 0; font-weight: bold; color: #333;\"\u003e6,000W (PF 0.99) | Terminal Block Input\/Output | 20 Batteries Included\u003c\/p\u003e\n\n\u003cp style=\"margin: 5px 0 0 0; color: #555;\"\u003e🔧 \u003cstrong\u003eDifficulty:\u003c\/strong\u003e 5\/5 (Electrician required) | 🎯 \u003cstrong\u003eIdeal for:\u003c\/strong\u003e Installers, SMEs, Server Rooms.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2\u003e6kVA Single-Phase Professional UPS: Pure Power Without Compromise\u003c\/h2\u003e\n\n\u003cp\u003eWhen operational continuity is vital, relying on a standard UPS is not enough. This \u003cstrong\u003e6000VA uninterruptible power supply\u003c\/strong\u003e is designed to deliver a true \u003cstrong\u003e6000W\u003c\/strong\u003e (Power Factor 0.99), offering significantly superior performance compared to common UPS devices that suffer from derating. Thanks to \u003cstrong\u003eOnline Double Conversion (VFI) technology\u003c\/strong\u003e, the load is always powered by a regenerated, perfect, and disturbance-free sine wave, with a 0 ms transfer time in case of a blackout.\u003c\/p\u003e\n\n\u003cp\u003eThe tower configuration on wheels and intelligent battery management make it the definitive choice for protecting server racks, industrial PLC systems, and sensitive electromedical equipment.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Analysis and Benefits for Installers\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e⚡ \u003cstrong\u003eTop Efficiency (PF 0.99):\u003c\/strong\u003e Utilize every single Ampere. With a near-unity ratio between VA and Watts, this UPS powers heavier loads than the competition, ensuring energy efficiency (up to 96% in Eco Mode).\u003c\/li\u003e\n\n\u003cli\u003e🛡️ \u003cstrong\u003eHardwired Security:\u003c\/strong\u003e To manage 6KW in total safety, the unit eliminates flying leads in favor of \u003cstrong\u003escrew terminal blocks\u003c\/strong\u003e for input and output. It includes accessible panel protection fuses.\u003c\/li\u003e\n\n\u003cli\u003e🔋 \u003cstrong\u003eHigh Voltage Power Bank:\u003c\/strong\u003e The system is powered by \u003cstrong\u003e20x 12V 7Ah batteries\u003c\/strong\u003e in series (240V DC Bus), ensuring a stable and long-lasting power reserve. Fast recharge to 90% in just 4 hours.\u003c\/li\u003e\n\n\u003cli\u003e🔧 \u003cstrong\u003eComprehensive Diagnostics:\u003c\/strong\u003e The LCD display provides real-time readings. The system automatically detects anomalies such as \"Wiring error\" or \"Fan fault.\" Remote management is possible via USB\/RS232 or an SNMP card (optional).\u003c\/li\u003e\n\n\u003cli\u003e🔄 \u003cstrong\u003eAbsolute Continuity:\u003c\/strong\u003e Equipped with an automatic Static Bypass: if the UPS overloads or fails, it switches to the mains without shutting down connected loads.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\u003ctbody\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower\u003c\/td\u003e\n\n\u003ctd style=\"padding: 10px;\"\u003e6000VA \/ 6000W (PF 0.99)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTechnology\u003c\/td\u003e\n\n\u003ctd style=\"padding: 10px;\"\u003eOnline Double Conversion\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWaveform\u003c\/td\u003e\n\n\u003ctd style=\"padding: 10px;\"\u003ePure Sine Wave\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eConnections\u003c\/td\u003e\n\n\u003ctd style=\"padding: 10px;\"\u003eScrew Terminal Blocks (Input\/Output)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBatteries\u003c\/td\u003e\n\n\u003ctd style=\"padding: 10px;\"\u003e20x 12V 7Ah (Total 240V DC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDimensions\u003c\/td\u003e\n\n\u003ctd style=\"padding: 10px;\"\u003e412 x 196 x 785 mm (Tower on wheels)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Protection\u003c\/td\u003e\n\n\u003ctd style=\"padding: 10px;\"\u003ePanel fuses\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNoise Level\u003c\/td\u003e\n\n\u003ctd style=\"padding: 10px;\"\u003e\u0026lt; 55 dBA at 1 meter\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSoftware\u003c\/td\u003e\n\n\u003ctd style=\"padding: 10px;\"\u003ePowerMaster+ (Win, Mac, Linux, VMware)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\n\u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Environment\u003c\/td\u003e\n\n\u003ctd style=\"padding: 10px;\"\u003e0-40°C \/ Max humidity 90%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cdiv style=\"background-color: #f8fafc; border-left: 5px solid #1e3a8a; padding: 20px; border-radius: 4px; display: flex; align-items: start; gap: 20px; margin-bottom: 25px;\"\u003e\n\n\u003cdiv style=\"flex: 1;\"\u003e\n\n\u003cp style=\"margin-top: 0; color: #1e3a8a; font-weight: bold;\"\u003e💡 Expert Advice:\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 0;\"\u003eEven for this 6KW size, do not underestimate the cable cross-section. I often see 2.5mm² cables used which, over long runs, cause voltage drops, causing the UPS to switch to battery unnecessarily. For input and output via terminal blocks, I recommend using cables of at least 4mm² or 6mm² (depending on the length of the line) terminated strictly with properly crimped eyelets. This ensures a firm and secure contact over time, avoiding overheating at the terminals.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cimg alt=\"Oniroview Expert\" style=\"width: 100px; height: 100px; object-fit: cover; border-radius: 50%; border: 2px solid #1e3a8a;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0260\/6222\/5485\/files\/Chi_siamo_oniroview.jpg?v=1751647335\"\u003e\n\n\u003c\/div\u003e\n\n\u003ch3\u003eComplete your project 🔗\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eSNMP Card:\u003c\/strong\u003e Essential for remote UPS monitoring and receiving email notifications in case of failure.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eFG16OR16 Cables:\u003c\/strong\u003e Suitable cable for fixed installation in conduits, ideal for connecting to the terminal block.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eQuick FAQs (For Installers)\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the battery runtime?\u003c\/strong\u003e\u003cbr\u003eIt depends on the applied load. With the 20 internal 7Ah batteries, micro-interruptions and safe server shutdown are managed. For longer runtimes, an external battery module (EBM) is required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow is it connected to the mains?\u003c\/strong\u003e\u003cbr\u003eThe unit does not have a plug. The connection is \"Hardwired\" (wired) to the rear terminal block. Ensure that the upstream protection in the electrical panel is correctly sized.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs it compatible with Generators?\u003c\/strong\u003e\u003cbr\u003eYes, the double conversion technology accepts variable input voltages (208-240Vac) and 50\/60Hz frequencies, purifying dirty generator power.\u003c\/p\u003e\n\n\u003ch3\u003ePackage Contents 📦\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e6KW Tower UPS\u003c\/li\u003e\n\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\n\u003cli\u003ePre-insulated eyelet terminals\u003c\/li\u003e\n\n\u003cli\u003eUSB cable for PC connection\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eWarranty and Safety ✅\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, RoHS.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eSafety:\u003c\/strong\u003e IP20 rating (Indoor installation).\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 24 Months Oniroview.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp style=\"margin-top: 20px; font-style: italic;\"\u003eShipping on insured pallet. For pre-sales technical assistance, the Oniroview team in Catania is at your disposal.\u003c\/p\u003e\n\n\n\u003c\/div\u003e","brand":"Alpha Elettronica","offers":[{"title":"Default Title","offer_id":52961808613715,"sku":"KUPST6000","price":2093.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0260\/6222\/5485\/files\/GruppodiContinuita10KWOnlineTower10000VA.jpg?v=1770327494","url":"https:\/\/zanqivorel.online\/en\/products\/gruppo-di-continuita-6kw-online-tower-6000va","provider":"Oniroview","version":"1.0","type":"link"}